重庆川仪4973电导池采用PES塑料作池体材料,抗腐蚀性强,可承受压力1.72MPa,温度140℃。电极材料有钦和石墨两种。可采用插入式、流通式等安装方式。4973,4973-001-333,4973-01-305,4973-10-333,4973-10-305,04973-X10-333-20
Chongqing
Chuanyi 4973 Series Conductivity Cells
are made of PES plastic which is of anti-corrosion and can bear the pressure of
1.72MPa as well as the high temperature of140℃. The electrode is made of Ti or
graphite. Insertion mounting and flow through mounting are selectable.
重庆川仪4973电导池的主要特点如下:
1.传感器构造坚固,连续测量可靠,温度*高至140℃,压力*高至1.72MPa0
2.电导池有很强的抗腐蚀能力,电极为钦材料(电极常数为0.01和0.1电导池)或高密度碳材料(电极常数为1.0和10.0电导池)。
3.可插入式和流通式安装,3/4"N尸下阳螺纹允许电导池长久安装在管道或罐上;电导池也用作实验室浸入型用于批量采样。
4.对于流通式应用,电导池能直接安装在过程流体中,或用一个需单独订货的3/4"管道丁型头安装在旁路流中,电导池已设计成保持电极和温度补偿器插在过程流中,保证电导池对溶液和温度的变化作出快速和正确的反应。
5.对于卫生型clean-in-place(CIP)管线系统,4973探头包括标准的3/2"或2"CIP连接件,适用于食品和饮料制药和化妆品,或生物技术工业。
Main Technical Features
1.The sensor is firm in
structure and thus can work continuously The highest temperature It can bear is140℃, and highest pressure 1.72MPa
2.This series旧of great anti-corrosion capacity
for the electrode is made of Ti (of which electrode constant is 0.01 and
conductivity cell 0.1) or graphite of high density (of which electrode constant
Is 1.0 and conductivity cell 10.0)
3.Suitable
for either insertion mounting or flow through mounting Conductivity cell can be
fixed on tube permanently by 3/4 NPT male screw thread.
4.For the flow through
mounting, conductivity cell can be installed In the fluid directly or be
assembled near the bypass flow. The conductivity cell has been designed to be
sensitive enough to the variation of solution and temperature
5.For the clean-in一place (CIP) tube system, 4973
consists of standard 3/2" or 2" CIP connector, and can be used in
food industry, beverage production, cosmetic production as well as
biotechnology industry
使用维护
.4973电导池维护量极小,只有当沉渣累积在电导池中,影响电导池的工作性能时,则需对电导池进行清洗。
.清洗一般采用无机酸,不仅快速、高效,并且十分充分;另一种方法采用高压水流冲掉附着的杂质,再用自来水和蒸馏水彻底清洗。
.电导池外壳由聚苯醚材料制成,所以禁止用丙酮、氯仿、甲苯或氯烃等试剂清洗。
.当测量值小于0.5 a s/cm电导率时,取样化验的值与在线表不具可比性,建议采用取样杯从在线表出口取样溢流进行实时测量比较,这样可以大大降低空气对水质的误差影响。
.Application and
Maintenance
.4973 series conductivity
cells require minimal maintenance. Only when the waster accumulated on the
cells affecting work performance, the cleaning is required.
.Generally, nonorganic acid
is used when cleaning, which is efficient and fast in response. High pressure
water stream can be used to wash out the deposit after which tap water or
distilled water is applied to make a final clean.
.For the conductivity cell is made of phenylene oxide, none of
acetone, chloroform toluene or chlorohydrocarbon can be used as cleanser.
.When conductivity is no
more than 0.5 N s/cm, real time measurement is much more reliable for it can
lower the influence of air on water quality