重庆川仪PS7200核电过程分析系统PS7200 Nuclear Power
Station Process Analysis System, 用于核电厂**壳内氢氧浓度的分析,通过了核电法规要求的辐照试验、电磁兼容试验、寿命试验、抗震试验等。
(1)anquan壳内大气的氢气和氧气分析
核电厂anquan壳出现事故后,对**壳内大气的氢气和氧气进行分析,可以为**壳出现事故的原因分析提供有力的参考依据。分析系统通过微小的取样管道将anquan壳内大气抽取到样气处理单元,经过温度、压力、湿度的处理后,提供给分析仪器进行分析,分析后的尾气,又送回到**壳内。
(1) H₂and
O₂ analysis in containment:
PS7200 series are designed to monitor the H₂and O₂in containment after accident happened in the nuclear power plant.
The monitoring result can provide a reference for containment accident
analysis. Gas in the containment is collected through the tiny sampling
pipeline and sent to the sample process unit where air temperature, pressure
and humidity are adjusted to meet the analysis requirements. Then the processed
gas is sent to the analyzer for analysis and the exhaust gas can be sent back
to the containment by the blower pump.
(2)废气系统氢气、氧气分析
核电厂废气系统氢气、氧气分析:通过对核电厂废气系统中的氢气、氧气分析,可以达到**控制的目的。分析系统通过从特定的取样区域引出样气到处理单元,经过温度、压力、湿度的处理,提供给分析仪器进行分析,分析后的尾气,又排放到指定的废气管道内。
(2) H₂ and O₂ analysis in exhaust gas:
Realize the safety control by analyzing the H₂ and O₂in the exhaust gas of nuclear power
plant.Sample gas is collected at the specific points and sent to the process
unit where gas temperature, pressure and humidity are adjusted to meet the
analysis requirements. Then the processed
gas is sent to the analyzer for analysis and exhausted through the off- gas
line.
PS7000系列过程分析成套系统包含:PS7100空分过程分析系统;PS7200核电过程分析系统;PS7300石油化工过程分析系统;PS7400烟气连续监测系统;PS7500水泥过程分析系统;PS7600冶金过程分析系统;PS7700能源燃气过程分析系统;PS7800空气质量监测系统;PS7900移动测试监测系统
序号 No. 检测点名称
Name of detecting point 测量组分及量程
Measuring component and range 分析仪器选型 Analyzertype
1 **壳内事故后氢气、氧气分析
H, and O, analysis after containment
accident H: 0-15% O:0-25% PS7200
2 废气系统氢气、氧气分析
H, and O, analysis in exhaust gas H,:
0-5%0:0-10% PA600Ex